4000-520-616
欢迎来到免疫在线!(蚂蚁淘生物旗下平台)  请登录 |  免费注册 |  询价篮
主营:主营:微管蛋白、肌动蛋白、小G蛋白、GAPs、GEFs
咨询热线电话
4000-520-616
当前位置: 首页 > 新闻动态 >
新闻详情
...laser on the fluorescence of labelled cell membrane |...
来自 : 发布时间:2025-03-14
AbstractNear infrared (NIR) laser light can have important reactions on live cells. For example, in a macroscopic scale, it is used therapeutically to reduce inflammation and in a single-cell scale, NIR lasers have been experimentally used to guide neuronal growth. However, little is known about how NIR lasers produce such behaviours on cells. In this paper we report effects of focussing a continuous wave 810-nm wavelength laser on in vivo 3T3 cells plasma membrane. Cell membranes were labelled with FM 4-64, a dye that fluoresces when associated to membrane lipids. Confocal microscopy was used to image cell membranes and perform fluorescence recovery after photobleaching (FRAP) experiments. We found that the NIR laser produces an increase of the fluorescence intensity at the location of laser spot. This intensity boost vanishes once the laser is turned off. The mean fluorescence increase, calculated over 75 independent measurements, equals 19%. The experiments reveal that the fluorescence rise is a growing function of the laser power. This dependence is well fitted with a square root function. The FRAP, when the NIR laser is acting on the cell, is twice as large as when the NIR laser is off, and the recovery time is 5 times longer. Based on the experimental evidence and a linear fluorescence model, it is shown that the NIR laser provokes a rise in the number of molecular associations dye-lipid. The results reported here may be a consequence of a combination of induced increments in membrane fluidity and exocytosis. IntroductionPlasma membrane dynamics is fundamental in cell secretion, signaling, movement, cell shape changes, cytokinesis, among other cellular processes. Cell membrane is in constant motion due to its characteristic fluid mosaic conformation, where the bilayer of amphiphilic phospholipids diffuse along the membrane plane into specific and heterogeneous membrane domains by translation, rotational motions around the axis perpendicular to the membrane, and by trans-bilayer diffusion in a less extent1,2. Cells continually adjust their membrane content and composition by two fundamental processes, the uptake of cell surface membrane called endocytosis, with which fluids or macromolecules may be introduced to the cell, and the fusion of vesicles at the cytoplasmic side of the membrane, called exocytosis, involved in secretion and expression of proteins on the cell membrane3,4,5. Endocytosis and exocytosis are fundamental events in cell protrusion and migration6,7,8,9.The interaction of a near infrared (NIR) laser beam with cells has been addressed from many different view angles. From a macroscopic perspective, low levels of NIR laser light are used to reduce pain, inflammation, nerve injuries and to promote tissue regeneration10,11,12. Studies of the influence of low-power helium-neon laser irradiation on selected peripheral blood cells have revealed the importance of photodynamic reactions on the ability of blood to transport oxygen and on immunomodulatory effects on leukocytes13. More recently it has been reported that low-intensity NIR laser radiation induces free radical generation and changes in enzymatic and anti-oxidative activities of cellular components14. Tightly focused NIR laser radiation has also been used as an attractant of cell projections. This has been described for fibroblasts15,16,17 and neurons18,19,20,21,22,23,24,25, opening a new perspective for a possible guidance cue. Although different cellular mechanisms have been suggested to take part in those phenomena, no model has yet gain consensus and in general, the biochemical and biophysical processes that take place when NIR light radiates cells are still poorly understood.In this paper, we analyze the effect of focused 810-nm laser stimulation on 3T3 fibroblast membrane dynamics. We use FM 4-64, a plasma membrane marker of the family of fluorescent amphiphilic styryl dyes, with a long hydrophobic tail able to interact into the lipid bilayer, whereas the positively charged head group of the molecule prevents the complete insertion into the membrane26. Between head and tail, two aromatic rings create the fluorophore. Its quantum yield strongly depends on the solvent polarity, such that in a polar medium like water, the fluorescence is more than two orders of magnitude dimmer than in a non-polar environment, therefore the fluorescence is much higher in the cell membrane than in the media, selectively staining cell surface membrane exposed to the dye26. FM dyes have been extensively used to study endo and exocytosis processes in different cell types26,27,28,29. Here we report previously unknown effects of the NIR laser focussed on the cell membrane: An increase in the fluorescence intensity of the membrane exposed to FM 4-64 at the location of the NIR laser spot, and an increase of the fluorescent recovery after photobleaching (FRAP). Our findings indicate that the fluorescence rise is due to an increase of FM-dye molecules incorporation into the cell membrane, and points towards an increase in membrane dynamic presumably driven by exocytosis events.ResultsObserved phenomena3T3 cells seeded on coverslips were stained with the membrane dye FM4-64. Cells were maintained at 37鈥壜癈 in a temperature-controlled chamber, immersed in culture medium that contained FM4-64. The complete protocols are described in the Methods Section. Confocal images were obtained by exciting the dye at 561-nm wavelength and detecting fluorescence in the spectral band ranging from 567.5 to 642.5鈥塶m. A continuous wave NIR laser of 810-nm wavelength was optionally focused on a preselected region of interest (ROI) of the cell membrane on the lamella or lamellipodia. The objective used for imaging and focusing the lasers was an oil immersion 60x magnification with numerical aperture of 1.4. The NIR laser power at the exit of the objective was generally 40鈥塵W, except for experiments specifically designed to study the laser power influence.When the NIR laser is turned on, the fluorescence in the ROI under the NIR radiation influence is seen to increase. An example is shown in Fig.1a,b. Figure1c shows the difference of images with laser ON (Fig.1b) minus the image with laser OFF (Fig.1a), putting in evidence that within the cell, only in the ROI radiated with the NIR laser the fluorescence increases. Two other examples obtained on different cells are shown in the Supplementary Fig.S1. The ROI on those examples do not contain any bright spot as opposed to the example shown in Fig.1.Figure 1Effect of a 810-nm continuous wave focused laser on fluorescence intensity. (a) Confocal image of a 3T3 cell previously stained with FM 4-64, with the presence of dye molecules in the medium. NIR laser is turned off in this image. (b) Same as in (a) but with the 810-nm laser focused on the centre of the yellow circle which represents the ROI where intensity average is computed. An intensity rise is clearly seen by comparing images in the two magnified regions shown. Cyan circles indicate the regions used to estimate background mean intensity. (c) Difference of images b minus a. (d) Blue line represents the mean relative intensity (Irel, Equation1) inside the ROI delimited by the yellow circle. Red line indicates the NIR laser power at the exit of the microscope objective. (e) Irel measured outside the cell (orange line) and on a cell without staining (blue line). (f) Same as in (c), but on a sample whose medium is label-free (blue line) and on a fixed cell immersed in medium that contained FM4-46 dye at 1, 1 渭M. For the intensity scales in frames (c), (d) and (e) to be comparable among each other, a second normalization is performed on the relative intensity such that plotted values are Irel(銆?b>ICELL鈥夆垝鈥?b>IBG銆?銆?b>IROI鈥夆垝鈥?b>IBG銆? where 銆堛€?operator represents a temporal average. See equation (1) for the definition of Irel.Full size imageTo evaluate this intensity variation compared to the intensity of the entire cell, we define the relative intensity as$${I}_{rel}=frac{{I}_{ROI}-{I}_{BG}}{{I}_{CELL}-{I}_{BG}},$$ where IROI, ICELL and IBG represent the mean intensities measured within the following three zones: the 4-渭m diameter circular ROI where the NIR laser was directed to, the entire cell (manually segmented in each case) and finally a background zone out of the cell. Note that Irel is independent of the background noise and of the overall fluorescence variation caused for example by photobleaching or fluctuation of the excitation laser power. An example of measured Irel,with and without exposure to the NIR laser, is plotted in Fig.1d as a function of time. In this figure, one can see that Irel boosts rapidly when the NIR laser is projected upon the cell and decreases down equally fast to its initial value when the laser is interrupted.Control measurementsA series of experiments were performed to discard eventual artefacts. Firstly, we measured Irel outside the cell. The result is shown by the orange line in Fig.1e. It indicates two facts: on the one hand, that NIR radiation was not leaking to the detector and on the other hand, that the free dye on the medium does not increase its fluorescence. Moreover, in the experiment shown in the Supplementary FigsS1a and S1b, the laser was located on an edge of the cell, irradiating partly on the cell and partly outside, and the fluorescence increases only on the cell membrane. All those evidences suggest that any fluorescence increase is due to the association dye-membrane, as further explained in the Discussion section. To discard some kind of non-linear autofluorescence of the cell, the NIR laser was directed to the membrane of an unmarked cell. No fluorescence was detected out of the noise. Irel showed no correlation with the NIR laser intensity (blue line in Fig.1e).Importance of free dye molecules in mediumTo further test that the effect under investigation has its origin in some change occurring in the cell-membrane dynamics, we performed measurements on cells that were stained and then fixed with paraformaldehyde at 4%. The dye used for this staining was FM4-64FX, the fixable analogue of FM4-64. During experiments, fixed cells were maintained under similar conditions as live cells, namely, the temperature was kept constant at 37鈥壜癈 in DMEM plus 10% FBS. The orange line in Fig.1f is an example of those measurements. It can be seen that the NIR laser does not have any influence on Irel on fixed cells. This is expected since the membrane of fixed cells is frozen due to covalent cross-links between their components. This strongly suggests the dependence of fluorescence changes in live cells upon molecular motion in the membrane. Moreover, in unfixed and stained cells exposed to NIR laser, but on dye-free medium, no evident increase of fluorescence was observed (Fig.1f), suggesting that changes in fluorescent intensity mediated by NIR radiation could be due to exocytosis that would increase membrane at the cell surface, and therefore incorporate new dye molecules. Indeed, this scenario is consistent with the fact that if there are no free dye molecules in the medium, no incorporation of new molecules is possible, which could explain the observed absence of fluorescence rise in that case.CharacterizationTo quantify and characterise the variation of the relative intensity resulting from the NIR laser influence, we define the ratio$${Q}_{I}=frac{{langle {I}_{rel}rangle }_{{T}_{ON}}}{{langle {I}_{rel}rangle }_{{T}_{OFF}}},$$ where the average in the denominator and numerator is performed over periods TOFF and TON that correspond to the 20-s period closer to the change of state of the NIR laser between OFF and ON, respectively. This construction is sketched in the inset of Fig.2a. In that same figure we show the histogram of the experimental values of QI, which is fitted with a log-normal probability (see Methods). The expected value and the variance of a random variable that has the fitted probability density function are E(QI)鈥?鈥?.19 and V(QI)鈥?鈥?.0092, respectively, which correspond fairly well with the mean and the variance of the data (overline{{Q}_{I}}=1.19) and ({sigma }_{{Q}_{I}}^{2}=0.0081). This means that the expected mean increase of the relative fluorescence intensity is 19%, with a standard deviation of (sqrt{0.0092}times 100=9.6 % ).Figure 2Statistical analysis of the fluorescence rise upon exposure to NIR laser. (a) Histogram of the intensity ratio QI fitted with a log-normal distribution. The inserted diagram illustrates the definition of QI as the ratio of average relative intensities measured when the NIR laser is on and off, the averages being calculated over the 20鈥塻 before and after the rise or fall of the NIR laser power. The 48 values of QIincluded in the histogram were obtained with an NIR laser power of 40鈥塵W. (b) QI as a function of laser power, p. Blue, orange, red and green data points correspond to individual experiments, each consisting of measuring QI as a function of NIR power. Each one of those data sets are fitted with the model indicated in the legend. Grey data points correspond to measurements performed without varying p. The complete data set, which consists of 75 values of QI, is fitted with the purple curve. The width of the light purple zone corresponds to six times the standard deviation of the computed fit.Full size imageOne evident question that comes to mind is how the fluorescence rise depends on the power of the NIR laser. We measured QI for NIR powers ranging from 5 to 40鈥塵W, in four independent experiments. Blue, orange, red and green data points plotted in Fig.2b correspond to those individual experiments. Each data set is fitted with a function of the form$${Q}_{I}(p)=1+asqrt{p},$$ p being the NIR laser power and a the free parameter for the fit. The choice of a square root dependence responds to a suspected relation between laser power and thermal velocity of the molecules (see Discussion section). All four experiments follow reasonably well this functional dependence, each with a different value of a. In Fig.2b, the grey data points represent the measured values of QI that were obtained in experiments where p was kept constant either at 40 or 60鈥塵W. All the data put together is fitted with same equation (3), obtaining a鈥?鈥?.03鈥壜扁€?.0017mW鈭?/2. The fit is plotted with the purple thick line in Fig.2b.Fluorescence recovery after photobleachingIn order to obtain more data about the kinetics of fluorescent changes mediated by NIR laser, the recovery of the fluorescence after photobleaching was measured in 11 experiments, in 7 of which the NIR laser was focused on the bleached region during the entire experiment, and in 4 of them the NIR laser was blocked, also during the whole experiment. The measured intensity was doubly normalized (see Methods) so that the resulting intensity, IFRAP, equals unity before photobleaching and is corrected for photofading caused by imaging after the bleach30. The results are shown in Fig.3, where the red and blue plots correspond to experiments done with and without the NIR laser. All the data in each of those two categories were fitted to an exponential function as indicated in the legend of Fig.3 and in the Methods section. Fluorescence recovery when the NIR laser is acting on the cell is almost twice as large as when the NIR laser is off, as deduced by the corresponding fitted values of Rf: 79鈥壜扁€? and 40鈥壜扁€?.5. The half recovery time given by the fit is much larger when the NIR laser is on (蟿鈥?鈥?0鈥壜扁€?.4 s) than when it is off (蟿鈥?鈥?鈥壜扁€?.6 s). Those results indicate that a higher proportion of FM molecules are incorporated at the bleached area when the NIR laser is ON, although with a smaller rate than when laser is OFF.Figure 3Fluorescence Recovery After Photobleaching (FRAP). Recovered Intensity IFRAP (see Methods section) is plotted as a function of time for seven experiments with NIR laser (red) and four experiments without NIR laser (blue). When turned on, the NIR laser was focused on the ROI of the cell membrane where the FRAP experiment was carried on. Photobleaching occurs when IFRAP鈥?鈥?. After that moment, fluorescence in the bleached ROI begins to recover. Bold curves are fits to the data following the standard model indicated in the legend, where Rf and 蟿 account for the fraction of intensity recovery and half recovery time, respectively. The width of the light blue and red zones for each instant correspond to the standard deviation of the computed fit.Full size imageDiscussionFM dyes are known to be brighter when associated with lipids (or other non-polar molecules such as prolactin proteins31) than in aqueous solution. The quantum yield 桅a of [dye-membrane] is considerably larger than that of the dye alone, 桅b. A schematic representation of the distribution of the FM4-64 molecules is given in Fig.4a. Assuming that the fluorescence measurements are performed in the linear regime so that photobleaching (except of course FRAP experiments) and quenching effects can be neglected, the measured fluorescence intensity can be modelled as:$$I=eta mathop{int }limits_{{rm{V}}}{rm{d}}{bf{r}},{n}_{V}({bf{r}})[{rm{alpha }}({bf{r}}){{rm{Phi }}}_{a}+(1-{rm{alpha }}({bf{r}})){{rm{Phi }}}_{b}]+{I}_{dark}.$$ Figure 4Plasma membrane stained with the fluorescent dye FM4-64. Dye molecules that are adhered to the lipids of the membrane are represented in red and those that move freely in the culture medium are drawn in blue. The NIR respective quantum yields are 桅a and 桅b. It is well known that FM4-64 fluoresces significantly more when associated to lipids than on polar solvent like water (桅a鈥?span >鈮?/span>鈥壩?sub>b). (a) Out of the cell, only molecules with quantum yield 桅b are found, whereas in the vicinity of the cell membrane both types of molecules coexist. (b) A NIR laser beam focused on the membrane provokes an increase of the proportion of dye molecules that are bound to lipids and the consequent rise of the fluorescent intensity when the cell is imaged in confocal microscopy.Full size imageIn this expression, all the photons emitted within the volume V are added up. nV represents the volumetric density of FM4-64 dye molecules, which is a function of the three-dimensional position vector r. the number of dye molecules that are bound to lipids is represented by 伪(r). The factor 畏 depends linearly on the excitation laser power, the voltage of the photomultiplier detector and of the dwell time. Idark represents the intensity measured in dark conditions (absence of signal). Using this model and our experimental evidence about the NIR laser impact on fluorescence, we show (Methods) that the NIR radiation is not modifying the properties of dye and that the fluorescence variation due to the NIR laser originates in an increase of the number of fluorescent associations [dye-lipid] in the ROI (See Fig.4b). This could occur presumably by a combination of a number of effects like membrane fluidity alteration, a modification in exo- and endocytosis rates, and exchange of dye molecules between the lipid bilayer and the medium.Most interestingly, we show (Methods) that$${Q}_{I}equiv frac{{I}_{re{l}_{ON}}}{{I}_{re{l}_{OFF}}}=frac{{alpha }_{RO{I}_{ON}}}{{alpha }_{RO{I}_{OFF}}}.$$ That is, QI equals the ratio of the fraction of dye molecules bound to lipids when the NIR is ON (({alpha }_{RO{I}_{ON}})) over that when the NIR is OFF (({alpha }_{RO{I}_{OFF}})), which gives a direct mean of quantifying the increment of dye molecules that are bound to lipids in the membrane as a consequence of the NIR radiation. The statistical analysis of QI (Fig.2a) indicates that the NIR laser at 40鈥塵W induces a mean increment of bounds [dye-lipid] of 19%.This scenario is further supported by the much higher FRAP when the NIR laser is present than when it is not. When the NIR laser is off, the fluorescence recovery can be understood in the classical way where fluorescent molecules within the membrane diffuse into the bleached spot and fluorescence recovers up to a certain level from which the mobile fraction of fluorescent molecules is determined30,32. When the NIR laser is acting on the membrane, the fluorescence recovery could come from two sources: in one hand, membrane-bound dye molecules diffusing in two dimensions and in the other hand, free dye molecules diffusing in three dimensions in the medium and getting bound to extra membrane available probably by exocytosis, increasing the fluorescent amount, as reported previously29. To investigate whether or not the timescales of the fluorescence intensity decay and rise are compatible with the possible explanations we are advancing, we gathered all the rise measurements in one plot and all the decay measurements in another plot and fitted exponential functions. The results are shown in Fig.5. The fluorescence rise and decay are well fitted by exponential functions with a time constants equal to 9.46鈥壜扁€?.05 s and 5.81鈥壜扁€?.71 s, respectively. Those values are consistent with endo and exocytosis events that can take place in timescales shorter than tens of seconds29,33 and even milliseconds34, and that can even happen simultaneously. The measured timescale of the fluorescence decay is longer than the timescales that have been reported for FM dye dissociation from lipids that range from milliseconds to seconds, depending on the dye concentration and membrane temperature35.Figure 5Timescale of fluorescence increase (a) and decay (b) as a result of NIR laser irradiation. Measured relative intensity values are represented by light cyan dots. The horizontal axis represents time minus time t0 at which the laser is turned on (a) and off (b). For positive values of t鈥夆垝鈥?i>t0, an exponential model is fitted to the data as indicated in the respective legend, where the time constant of each exponential model is also indicated. The width of the cyan zones for each instant correspond to six times the standard deviation of the computed fit.Full size imageIt has been shown36 that 810-nm laser radiation, with power ranging from 10 to 400鈥塵W, can induce an increase in the fluidity of isolated erythrocytes membranes and activate membrane ATPasa, in a laser-power-dependent way. In our results, NIR irradiation could similarly be increasing membrane fluidity, however, unlike experiments on isolated cell membrane, our in vivo protocol allowed us to observe an extra contribution to fluorescent recovery that could be explained by other cell membrane events as exocytosis. Interestingly, it has been reported37,38,39 that low-energy NIR laser radiation induces the secretion and release of interleukins and growth factors in several cells like macrophages, keratinocytes and fibroblasts. The same kind of radiation can have a therapeutic effect in inflammation and wound healing by secretion of inflammatory mediators40,41,42,43. However, to our knowledge, no direct experimental evidence of cellular mechanisms driving secretion is available.Also, we find that QI (or, from Equation5, the fraction of dye molecules adhered to membrane lipids) can be adjusted with a square root dependence of the laser power (Fig.2b). This functional relation is reminiscent of the speed of molecules in Brownian motion as a function on the thermal energy in a fluid. An increase of temperature due to the NIR laser would be consistent with the increase of dye molecules being introduced between lipid molecules into the membrane. However, several authors44,45,46 have reported that NIR optical tweezers, which use a similar laser beam as that used here, provoke a temperature increase of only a few degrees Kelvin on biological samples immersed in water, where the typical temperature ranges from 298 to 310 掳K. For example, a steady temperature increase of 1.9 掳C is calculated46 for a 1064-nm 100鈥塵W laser in the focus of a microscope objective of 1.3 numerical aperture, in water, after only a few milliseconds. Considering the at that wavelength the absorption coefficient of water is approximately 5 times higher than at 810-nm47, that the spot area given by a 1.2鈥塏.A. objective is 1.36 times larger than that given by a 1.4鈥塏.A. (as ours), and that the laser power used in our experiments is 40% of that used by Catal谩 et al.46, it is safe to consider that the temperature increase due to the 810-nm laser is lower than 1鈥壜癈. Such a small increase in temperature could hardly account for the measured increase in dye-lipid bounds, under the light of, for example, the results of a study of the temperature dependence of the structure of Dioleoylphosphatidylcholine bilayers48. It has been reported49 that a large focalized temperature increase in a mono-layer lipid membrane makes the membrane permeable to ions even in the absence of ion channels. In that investigation, the authors illuminate, with a visible laser, gold nanoparticles that upon excitation of the plasmon resonance transfer heat to the membrane. In our case, either the local temperature rise is much larger than the few Kelvins expected from the literature, or there are additional phenomena involved.ConclusionOur study shows that a near NIR laser focused on a live 3T3 cell promotes binding of free dye molecules floating in the culture medium with lipid molecules in the membrane. Such a result is consistent with the laser modifying the molecular dynamics in the membrane presumably due to two factors: membrane fluidity and exocytosis, however definitive explanations need further investigations. To the best of our knowledge, this is the first time that the influence of a focused NIR laser on the lipid dynamics of a live cell plasma membrane is demonstrated. A complete understanding of NIR laser radiation on living cells is far from being achieved. Studies of the rheological properties of bilayer lipid membranes under the influence of an NIR laser can bring important clues. Those biophysical experiments should be complemented with investigations of the effect of NIR laser radiation on the biochemistry of molecular receptors and signalling processes for wider perspective to be attained. Understanding the interaction of NIR laser with live cells can lead to the development of innovative protocols and therapies.MethodsReagentsFM 4-64 Dye (N-(3-Triethylammoniumpropyl)-4-(6-(4-(Diethylamino) Phenyl) Hexatrienyl) Pyridinium Dibromide) and its fixable analog FM 4-64 FX were purchased from Invitrogen. Hank鈥檚 Balanced Salt Solution (HBSS), Dulbecco鈥檚 modified Eagle鈥檚 medium (DMEM), bovine-inactivate fetal serum (FBS), N-2-hydroxyethylpiperazine-N-2-ethane sulfonic acid (HEPES 1鈥塎), Trypsin-EDTA 1x and Penicillin/streptomycin were purchased from Gibco BRL Life Technologies. Collagen Type I, phosphate-buffered saline (PBS), Paraformaldehyde (PFA) and Dimethyl Sulfoxide (DMSO) were purchased from Sigma-Aldrich.Cell cultureNIH3T3 cells were cultured in DMEM supplemented with 10% FBS and 1% penicillin/streptomycin in a 37鈥壜癈 and 5% CO2 incubator. The cells were gently washed with PBS 1x and detached from the culture dish by exposing them to 1鈥塵L Trypsin-EDTA 1x for 5鈥塵in at 37鈥壜癈 with 5% CO2. Then 3鈥塵L DMEM was added to the culture and the solution obtained was centrifuged at 1000鈥塺pm for 5鈥塵in. The pellet was drained and then homogenized with 1鈥塵L supplemented DMEM. Cell density was measured using a hemocytometer after staining with trypan blue. A stock of 2鈥壝椻€?04 cells was maintained in supplemented DMEM medium and 3鈥壝椻€?03 cells were cultured on coverslips previously treated with 2鈥壜礸/mL of collagen type I kept at 37鈥壜癈 in a humidified atmosphere with 5% CO2 for 2 days. The treatment of sterile coverslips with Collagen consisted in adding 200鈥壜礚 of the solution on the coverslip and incubated at 37鈥壜癈 for 1鈥塰 and washed once with PBS.Sample preparationCells were labelled by incubating them for 20鈥塵inutes at 37鈥壜癈 in a solution of FM4-64 at a final concentration of consisting of 5鈥壜礸/mL in HBSS (FM 4-64 staining solution). After the staining incubation, the coverslip was installed inside a Chamlide magnetic chamber filled with 1.5鈥塵L of a solution constitued of DMEM plus 10% FBS, buffered by HEPES 10鈥塵M plus 1鈥壜礚 of FM 4-64 solution at 1鈥塵g/mL in DMSO (FM 4-64 register solution). The chamber was placed in a Tokai hit top stage incubator to maintain the sample at 37鈥壜癈. For the control experiments where the cell medium was free of dye molecules, prior to putting the coverslip inside the magnetic chamber, the cells were gently washed with PBS 1x and the chamber was filled with DMEM plus 10% FBS, buffered by HEPES 10鈥塵M. For the experiments on fixed cells, the cells were first labelled following the same procedure as described above but instead of using FM 4-64 we used FM 4-64 FX. Then cells were fixed with PFA at 4%.Optical SetupA scheme of the optical layout is provided in Fig.6. The instrument is based on a Nikon Eclipse Ti inverted microscope equipped with a C1si confocal system. The CW Ti:Sa laser is positioned using a galvanometric mirrors pair entering through the rear port. The NIR beam is imaged in the back focal plane of the objective by means of the conjugation optics and reflected by the short-pass (FF720-SDi01-25鈥壝椻€?6) dichroic mirror. The power of the NIR laser is controlled by measuring the power reflected by the power meter after a polarizing BS cube when rotating a half-wave retarder. Transmission images can be acquired either using the transmission detector when using the confocal unit or using a CMOS camera (DCC1545M-Thorlabs) when illuminating with the standard halogen lamp. During the experiments the sample is mounted inside a chamber with temperature held at 37鈥壜癈 using a Tokai Hit stage top incubator.Figure 6Optical layout of the experiments. The instrument is based on a Nikon Eclipse Ti confocal microscope. A Ti:Sa laser operating in CW mode provides the 810-nm radiation that enters through one of the rear ports of the microscope and is reflected by a dichroic mirror. The infrared spot position is controlled with galvanometric mirrors labelled Galvo X and Galvo Y. Lenses 1 through 4 ensure beam expansion and conjugation of the galvanometric mirrors to the objective pupil. The 810-nm laser power is controlled with a half-wave plate and a polarising beam splitter that sends one polarization direction to a power meter and the other to the microscope. The sample is mounted inside a chamber with temperature held at 37鈥壜癈 using a Tokai Hit stage top incubator.Full size imageMeasurementsFluorescence Intensity measurementsThe microscope control and image acquisition were done using software NIS-Elements (Nikon Instruments Microscopes and Digital Imaging Systems) software. Fluorophores were excited with the 561-nm laser of the confocal microscope at 5% of its maximum power. Images consisting of 512鈥壝椻€?12 pixels were acquired every 4.52鈥塻 with unidirectional scan. For FRAP experiments, five frames every 15.96鈥塻 were taken prior to photobleaching, then the ROI on the sample was expose three times to the excitation laser at its maximum power. After that, images for the measurements of the fluorescence recovery were obtained as described before (every 4.52鈥塻), for at least two more minutes. The detector of transmitted light was used as a monitor of the NIR laser status (ON or OFF).NIR laser power measurementsThe polarizing beam splitter (Fig.6) in the 810-nm laser path divides the laser radiation in two complementary parts, the proportion of which is determined by the rotation angle of the half-wave plate retarder. The power that is directed to the microscope equals the total laser power minus the power that is directed to the power-meter. To take into account losses in the optical path, prior to the experiments, the power at the power-meter was cross-calibrated to the power measured at the exit of the microscope objective with another power-meter. This calibration was then used to determine the NIR laser power at the sample by measuring the power at the power-meter shown in Fig.6.Data analysis and fittingLog-normal probability density functionThe histogram of QI values (Fig.2a) is fitted with a log-normal probability function of the form:$$f({Q}_{I})=frac{1}{({Q}_{{rm{I}}}-{Q}_{{rm{c}}}){sigma }_{I}sqrt{2pi }}{{rm{e}}}^{frac{-{(mathrm{log}({Q}_{I}-{Q}_{c})-{mu }_{I})}^{2}}{2{{sigma }_{I}}^{2}}}$$ The parameter values that produced the best fit were Qc鈥?鈥?.92, 渭I鈥?鈥夆垝1.37 and 蟽I鈥?鈥?.34. Fitting was computed using SciPy statistical lognorm package under python. Following the documentation of that package, the expected value E(QI) and the variance V(QI) of such a random variable are calculated by$$E({Q}_{I})={{rm{e}}}^{{mu }_{I}+frac{{{sigma }_{I}}^{2}}{2}}+{Q}_{c}$$ $$V({Q}_{I})=({{rm{e}}}^{{{sigma }_{I}}^{2}}-1){{rm{e}}}^{2{mu }_{I}+{{sigma }_{I}}^{2}}.$$ For the parameter values given by the fit, we obtain E(QI)鈥?鈥?.19 and V(QI)鈥?鈥?.0092.FRAPThe analysis of the FRAP was based on the double normalization of intensity measurements, which involves normalization of the recovery signal to the average prebleach signal and, at the same time, takes into account the loss of signal due to photofading during postbleach imaging. We also correct for the background intensity. Let us define the background corrected mean intensities in the ROI and in the whole cell as:$${I}_{ROI}^{text{\'}}(t)={I}_{ROI}(t)-{I}_{BG}(t)$$ $${I}_{CELL}^{text{\'}}(t)={I}_{CELL}(t)-{I}_{BG}(t)$$ (10) The ROI is photobleached at time tp. The normalized intensity is:$${I}_{FRAP}(t)=frac{{I}_{ROI}^{text{\'}}(t)-{I}_{ROI}^{text{\'}}({t}_{p})}{{langle {I}_{ROI}^{text{\'}}rangle }_{t {t}_{p}}-{I}_{ROI}^{text{\'}}({t}_{p})}times frac{{langle {I}_{CELL}^{text{\'}}rangle }_{t {t}_{p}},}{{I}_{CELL}^{text{\'}}(t)}$$ (11) where the symbol 銆堛€?span >(t {t}_{p}) represents averaging before photobleaching. IFRAP(t) is fitted to Rf(1鈥夆垝鈥?i>e鈭?i>t/蟿).Demonstration of insensitivity of quantum yields 桅 a and 桅 b to the NIR laserA good approximation to Equation4 is obtained by considering volume V being a cylinder of base A and altitude h. The fluorescence intensity averaged over area A can be written as:$${I}_{A}equiv frac{I}{A}=heta [{{rm{Phi }}}_{a}bar{alpha {n}_{A}}+{{rm{Phi }}}_{b}bar{(1-alpha ){n}_{A}}]+bar{{I}_{dark}}$$ (12) The bar indicates an average over surface A. Considering that the surface density of dye molecules nA and 伪 are statistically independent, (overline{alpha {n}_{A}}=bar{alpha },overline{{n}_{A}}) and (overline{(1-alpha ){n}_{A}}=(1-bar{alpha })overline{{n}_{A}}). Moreover, to simplify mathematical notations, let the averaging over a region be noted by a subindex such that 伪A鈥夆墶鈥?span >({alpha }_{A}equiv bar{alpha }) . We can safely consider that the spatial distribution of the dye molecules is homogeneous and simply designated by (nequiv overline{{n}_{A}}). The same consideration applies to the dark current so that ({I}_{dark}=bar{{I}_{dark}}) for any region. Equation12 is thus simplified as:$${I}_{A}=heta [{{rm{Phi }}}_{a}{alpha }_{A}n+{{rm{Phi }}}_{b}(1-{alpha }_{A})n]+{I}_{dark}.$$ (13) Measurements out of the cellFor the control experiments performed out of the cell (see Fig.1e), the relative intensity used is:$${I}_{re{l}_{OUT}}=frac{{I}_{OUT}}{{I}_{BG}}$$ (14) The numerator is obtained from Equation13 by replacing subindex A by OUT. Since out of the cell the abundance of lipids can be neglected, ({alpha }_{OUT}simeq 0), thus$${I}_{OUT}simeq heta n{{rm{Phi }}}_{b}+{I}_{dark}.$$ (15) The only parameter in last equation that could imaginably vary as a consequence of the NIR laser is the quantum yield of dye molecules unbound to lipids 桅b which would take values 桅bON or 桅bOFF depending on the NIR laser status. The intensity on the background is always$${I}_{BG}simeq heta n{{rm{Phi }}}_{{b}_{OFF}}+{I}_{dark}.$$ (16) As ({I}_{re{l}_{OUT}}) is not seen to depend on the NIR laser power, we conclude that this radiation does not affect the quantum yield of the dye molecules that are unbound to lipids:$${{rm{Phi }}}_{{b}_{ON}}={{rm{Phi }}}_{{b}_{OFF}}={{rm{Phi }}}_{b}.$$ (17) Measurements on the cellThe relative intensity measured on the cell membrane with NIR laser ON and OFF is respectively given by$${I}_{re{l}_{ON}}=frac{{I}_{RO{I}_{ON}}-{I}_{BG}}{{I}_{CEL{L}_{ON}}-{I}_{BG}}$$ (18) $${rm{and}},{I}_{re{l}_{OFF}}=frac{{I}_{RO{I}_{OFF}}-{I}_{BG}}{{I}_{CEL{L}_{OFF}}-{I}_{BG}}.$$ (19) Considering that the cell area is much larger than the area influenced by the NIR spot, it is reasonable to make the approximation ({I}_{CEL{L}_{ON}}simeq {I}_{CEL{L}_{OFF}}={I}_{CELL}). The three terms involved in Equation18:$${I}_{RO{I}_{ON}}=heta [{{rm{Phi }}}_{{a}_{ON}}{alpha }_{RO{I}_{ON}}n+{{rm{Phi }}}_{b}(1-{alpha }_{RO{I}_{ON}})n]+{I}_{dark}$$ (20) $${I}_{CELL}=heta [{{rm{Phi }}}_{a}{alpha }_{CELL}n+{{rm{Phi }}}_{b}(1-{alpha }_{CELL})n]+{I}_{dark}$$ (21) $${I}_{BG}simeq heta n{{rm{Phi }}}_{b}+{I}_{dark}$$ (22) lead to a simplified expression for the relative intensity for the NIR laser ON:$${I}_{re{l}_{ON}}=frac{({{rm{Phi }}}_{{a}_{ON}}-{{rm{Phi }}}_{b}){alpha }_{RO{I}_{ON}}}{({{rm{Phi }}}_{a}-{{rm{Phi }}}_{b}){alpha }_{CELL}}.$$ (23) Equivalently, the relative intensity for the case where the NIR laser is OFF becomes$${I}_{re{l}_{OFF}}=frac{({{rm{Phi }}}_{a}-{{rm{Phi }}}_{b}){alpha }_{RO{I}_{OFF}}}{({{rm{Phi }}}_{a}-{{rm{Phi }}}_{b}){alpha }_{CELL}}=frac{{alpha }_{RO{I}_{OFF}}}{{alpha }_{CELL}}.$$ (24) Now, we find that when there is no free dye in the medium, the NIR laser does not induce any change in the relative intensity (see Fig.1f), thus ({I}_{re{l}_{ON}}={I}_{re{l}_{OFF}}). Furthermore, in such condition the fraction of dye molecules bound to lipids cannot increase and we assume that it does not decrease either, because the lipophilic tail of FM4-64 molecules maintains them bound to the lipid membrane. Consequently, in that case, ({alpha }_{RO{I}_{ON}}={alpha }_{RO{I}_{OFF}}). From the last two equalities and Equations23 and 24, it is straightforward to show that$${{rm{Phi }}}_{{a}_{ON}}={{rm{Phi }}}_{a}$$ (25) Which means that the NIR laser is not affecting the quantum yield of FM4-64 when bound to lipids. Using Equations23, 24 and 25, the intensity ratio QI defined in Equation2 becomes$${Q}_{I}equiv frac{{I}_{re{l}_{ON}}}{{I}_{re{l}_{OFF}}}=frac{{alpha }_{RO{I}_{ON}}}{{alpha }_{RO{I}_{OFF}}}$$ (26) Analysis SoftwareData were analysed using ImageJ (version 2.0.0) and a series of self-developed packages and programs written in Jython and in Python. Data and analysis routines are available from the corresponding author upon reasonable request. References1.Edidin, M. Rotational and Translational Diffusion in Membranes. Annu. Rev. Biophys. Bioeng. 3, 179鈥?01 (1974).CAS聽 Article聽Google Scholar聽 2.Go帽i, F. M. The basic structure and dynamics of cell membranes: An update of the Singer鈥揘icolson model. Biochim. Biophys. Acta - Biomembr. 1838, 1467鈥?476 (2014).Article聽Google Scholar聽 3.Alberts, B. et al. Molecular Biology of the Cell 4th Edition: International Student Edition. (Routledge, 2002).4.Chieregatti, E. Meldolesi, J. Regulated exocytosis: New organelles for non-secretory purposes. Nature Reviews Molecular Cell Biology 6, 181鈥?87 (2005).CAS聽 Article聽Google Scholar聽 5.Doherty, G. J. McMahon, H. T. Mechanisms of Endocytosis. Annu. Rev. Biochem. 78, 857鈥?02 (2009).CAS聽 Article聽Google Scholar聽 6.de Curtis, I. Meldolesi, J. Cell surface dynamics - how Rho GTPases orchestrate the interplay between the plasma membrane and the cortical cytoskeleton. J. Cell Sci. 125, 4435鈥?444 (2012).Article聽Google Scholar聽 7.Tojima, T. Intracellular signaling and membrane trafficking control bidirectional growth cone guidance. Neurosci. Res. 73, 269鈥?74 (2012).CAS聽 Article聽Google Scholar聽 8.DeMali, K. A. Coupling membrane protrusion and cell adhesion. J. Cell Sci. 116, 2389鈥?397 (2003).CAS聽 Article聽Google Scholar聽 9.Worthylake, R. A. Burridge, K. RhoA and ROCK Promote Migration by Limiting Membrane Protrusions. J. Biol. Chem. 278, 13578鈥?3584 (2003).CAS聽 Article聽Google Scholar聽 10.Huang, Y.-Y., Chen, A. C.-H., Carroll, J. D. Hamblin, M. R. Biphasic Dose Response in Low Level Light Therapy. Dose-Response 7, 358鈥?83 (2009).Article聽Google Scholar聽 11.Rochkind, S. et al. Efficacy of 780-nm Laser Phototherapy on Peripheral Nerve Regeneration after Neurotube Reconstruction Procedure (Double-Blind Randomized Study). Photomed. Laser Surg. 25, 137鈥?43 (2007).Article聽Google Scholar聽 12.Zivin, J. A. et al. Effectiveness and Safety of Transcranial Laser Therapy for Acute Ischemic Stroke. Stroke 40, 1359鈥?364 (2009).Article聽Google Scholar聽 13.W膮sik, M. et al. The influence of low-power helium-neon laser irradiation on function of selected peripheral blood cells. J. Physiol. Pharmacol. 58, 729鈥?37 (2007).ADS聽 PubMed聽Google Scholar聽 14.Kujawa, J. et al. The effect of near-infrared MLS laser radiation on cell membrane structure and radical generation. Lasers Med. Sci. 29, 1663鈥?668 (2014).Article聽Google Scholar聽 15.Albrecht-Buehler, G. Surface extensions of 3T3 cells towards distant infrared light sources. J. Cell Biol. 114, 493鈥?02 (1991).CAS聽 Article聽Google Scholar聽 16.Albrecht-Buehler, G. A long-range attraction between aggregating 3T3 cells mediated by near-infrared light scattering. Proc. Natl. Acad. Sci. USA 102, 5050鈥?055 (2005).ADS聽 CAS聽 Article聽Google Scholar聽 17.Avila, R. et al. Optical tweezers experiments for fibroblast cell growth stimulation. In Proceedings of SPIE - The International Society for Optical Engineering (eds Popp, J., Tuchin, V. V., Matthews, D. L., Pavone, F. S. Garside, P.) 9129, 91291U (2014).18.Carnegie, D. J., Stevenson, D. J., Mazilu, M., Gunn-Moore, F. Dholakia, K. Guided neuronal growth using optical line traps. Opt. Express 16, 10507鈥?0517 (2008).ADS聽 CAS聽 Article聽Google Scholar聽 19.Carnegie, D. J., 膶i啪m谩r, T., Baumgartl, J., Gunn-Moore, F. J. Dholakia, K. Automated laser guidance of neuronal growth cones using a spatial light modulator. J. Biophotonics 2, 682鈥?92 (2009).Article聽Google Scholar聽 20.Ehrlicher, A. et al. Guiding neuronal growth with light. Proc. Natl. Acad. Sci. 99, 16024鈥?6028 (2002).ADS聽 CAS聽 Article聽Google Scholar聽 21.Ehrlicher, A. et al. Optical Neuronal Guidance. Methods in Cell Biology 83, 495鈥?20 (2007).CAS聽 Article聽Google Scholar聽 22.Graves, C. E., McAllister, R. G., Rosoff, W. J. Urbach, J. S. Optical neuronal guidance in three-dimensional matrices. J. Neurosci. Methods 179, 278鈥?83 (2009).Article聽Google Scholar聽 23.Mohanty, S. K., Sharma, M., Panicker, M. M. Gupta, P. K. Controlled induction, enhancement, and guidance of neuronal growth cones by use of line optical tweezers. Opt. Lett. 30, 2596 (2005).ADS聽 Article聽Google Scholar聽 24.Stevenson, D. J. et al. Optically guided neuronal growth at near infrared wavelengths. Opt. Express 14, 9786鈥?793 (2006).ADS聽 CAS聽 Article聽Google Scholar聽 25.Mathew, M. et al. Signalling effect of NIR pulsed lasers on axonal growth. J. Neurosci. Methods 186, 196鈥?01 (2010).Article聽Google Scholar聽 26.Gaffield, M. A. Betz, W. J. Imaging synaptic vesicle exocytosis and endocytosis with FM dyes. Nat. Protoc. 1, 2916鈥?921 (2007).Article聽Google Scholar聽 27.Cochilla, A. J., Angleson, J. K. Betz, W. J. Monitoring Secretory Membrane With Fm1-43 Fluorescence. Annu. Rev. Neurosci. 22, 1鈥?0 (1999).CAS聽 Article聽Google Scholar聽 28.Danielsen, E. M. Probing endocytosis from the enterocyte brush border using fluorescent lipophilic dyes: lipid sorting at the apical cell surface. Histochem. Cell Biol. 143, 545鈥?56 (2015).CAS聽 Article聽Google Scholar聽 29.Smith, C. B. Betz, W. J. Simultaneous independent measurement of endocytosis and exocytosis. Nature 380, 531鈥?34 (1996).ADS聽 CAS聽 Article聽Google Scholar聽 30.Phair, R. D. Misteli, T. High mobility of proteins in the mammalian cell nucleus. Nature 404, 604鈥?09 (2000).ADS聽 CAS聽 Article聽Google Scholar聽 31.Angleson, J. K., Cochilla, A. J., Kilic, G., Nussinovitch, I. Betz, W. J. Regulation of dense core release from neuroendocrine cells revealed by imaging single exocytic events. Nat. Neurosci. 2, 440鈥?46 (1999).CAS聽 Article聽Google Scholar聽 32.Reits, E. A. J. Neefjes, J. J. From fixed to FRAP: measuring protein mobility and activity in living cells. Nat. Cell Biol. 3, E145 (2001).CAS聽 Article聽Google Scholar聽 33.Thomas, P., Lee, A. K., Wong, J. G. Almers, W. A triggered mechanism retrieves membrane in seconds after Ca2+- stimulated exocytosis in single pituitary cells. J. Cell Biol. 124, 667鈥?75 (1994).CAS聽 Article聽Google Scholar聽 34.Neves, G. Lagnado, L. The kinetics of exocytosis and endocytosis in the synaptic terminal of goldfish retinal bipolar cells. J. Physiol. 515, 181鈥?02 (1999).CAS聽 Article聽Google Scholar聽 35.Wu, Y., Yeh, F. L., Mao, F. Chapman, E. R. Biophysical characterization of styryl dye-membrane interactions. Biophys. J. 97, 101鈥?09 (2009).ADS聽 CAS聽 Article聽Google Scholar聽 36.Kujawa, J. et al. Effect of Low-Intensity (3.75-25 J/cm2) Near-Infrared (810 nm) Laser Radiation on Red Blood Cell ATPase Activities and Membrane Structure. J. Clin. Laser Med. Surg. 22, 111鈥?17 (2004).Article聽Google Scholar聽 37.Young, S., Bolton, P., Dyson, M., Harvey, W. Diamantopoulos, C. Macrophage responsiveness to light therapy. Lasers Surg. Med. 9, 497鈥?05 (1989).CAS聽 Article聽Google Scholar聽 38.Yu, H.-S., Chang, K.-L., Yu, C.-L., Chen, J.-W. Chen, G.-S. Low-Energy Helium-Neon Laser Irradiation Stimulates Interleukin-1伪 and Interleukin-8 Release from Cultured Human Keratinocytes. J. Invest. Dermatol. 107, 593鈥?96 (1996).CAS聽 Article聽Google Scholar聽 39.Yu, W., Naim, J. O. Lanzafame, R. J. The effect of laser irradiation on the release of BFGF from 3T3 fibroblasts. Photochem. Photobiol. 59, 167鈥?70 (1994).CAS聽 Article聽Google Scholar聽 40.Costa Carvalho, J. L. et al. The chemokines secretion and the oxidative stress are targets of low鈥恖evel laser therapy in allergic lung inflammation. J. Biophotonics 9, 1208鈥?221 (2016).CAS聽 Article聽Google Scholar聽 41.G贸ralczyk, K., Szyma艅ska, J., Szot, K., Fisz, J. Ro艣膰, D. Low-level laser irradiation effect on endothelial cells under conditions of hyperglycemia. Lasers Med. Sci. 31, 825鈥?31 (2016).Article聽Google Scholar聽 42.Hochman, B. et al. Low-level laser therapy and light-emitting diode effects in the secretion of neuropeptides SP and CGRP in rat skin. Lasers Med. Sci. 29, 1203鈥?208 (2014).Article聽Google Scholar聽 43.Nicholas, K. et al. Low鈥恜ower helium: Neon laser irradiation enhances production of vascular endothelial growth factor and promotes growth of endothelial cells in vitro. Lasers Surg. Med. 28, 355鈥?64 (2001).Article聽Google Scholar聽 44.Liu, Y. et al. Evidence for localized cell heating induced by infrared optical tweezers. Biophys. J. 68, 2137鈥?144 (1995).ADS聽 CAS聽 Article聽Google Scholar聽 45.Celliers, P. M. Conia, J. Measurement of localized heating in the focus of an optical trap. Appl. Opt. 39, 3396鈥?407 (2000).ADS聽 CAS聽 Article聽Google Scholar聽 46.Catal脿, F., Mars脿, F., Montes-Usategui, M., Farr茅, A. Mart铆n-Badosa, E. Influence of experimental parameters on the laser heating of an optical trap. Sci. Rep. 7, 16052 (2017).ADS聽 Article聽Google Scholar聽 47.Kou, L., Labrie, D. Chylek, P. Refractive indices of water and ice in the 0.65 to 2.5 碌m spectral range. Appl. Opt. 32, 3531 (1993).ADS聽 CAS聽 Article聽Google Scholar聽 48.Pan, J., Tristram-Nagle, S., Ku膷erka, N. Nagle, J. F. Temperature dependence of structure, bending rigidity, and bilayer interactions of dioleoylphosphatidylcholine bilayers. Biophys. J. https://doi.org/10.1529/biophysj.107.115691 (2008).Article聽 PubMed聽 PubMed Central聽Google Scholar聽 49.Urban, P., Kirchner, S. R., M眉hlbauer, C., Lohm眉ller, T. Feldmann, J. Reversible control of current across lipid membranes by local heating. Sci. Rep. 6, 1鈥? (2016).Article聽Google Scholar聽 Download referencesAcknowledgementsThe authors acknowledge financial support from the Spanish Ministry of Economy and Competitiveness (MINECO) through the 鈥淪evero Ochoa鈥?program for Centres of Excellence in R D (SEV-2015-0522), from Fundaci贸 Privada Cellex, Fundaci贸n Mig-Puig and from Generalitat de Catalunya through the CERCA program鈥? J.A., M.M. and P.L.-A. acknowledge support from MINECO, grant FIS2016-80455-R (AEI/FEDER, UE). R.A. and P.L.-A. acknowledge support from TV3 Foundation鈥檚 La Marat贸 (20141730). R.A. obtained support from UNAM-PAPIIT grant IN111815 and CIC-UNAM, E.T. received an international stay grant from SEP, through the International Affairs Office of Universidad Veracruzana, N.M.V. was a CONACYT fellow number 284606 of the Doctorado en Ciencias de la Salud, of Instituto de Ciencias de la Salud de la Universidad Veracruzana, and received a travel grant from Red de Biofot贸nica, CONACYT number F0003-2018-03-294910. We are deeply grateful to ICFO staff, especially the SLN and BIOLAB facilities.Author informationAffiliationsCentro de F铆sica Aplicada y Tecnolog铆a Avanzada, Universidad Nacional Aut贸noma de M茅xico (UNAM), A. P. 1-1010, Juriquilla, 76000, Quer茅taro, MexicoRemy AvilaICFO-Institut de Ciencies Fotoniques, The Barcelona Institute of Science and Technology, 08860, Castelldefels, Barcelona, SpainRemy Avila,聽Norma Medina-Villalobos,聽Jordi Andilla,聽Mar铆a Marsal聽 聽Pablo Loza-AlvarezInstituto de Ciencias de la Salud, Universidad Veracruzana, Avenicda Luis Castelazo Ayala s/n, Xalapa, 91190, Veracruz, MexicoElisa Tamariz聽 聽Norma Medina-VillalobosAuthorsRemy AvilaView author publicationsYou can also search for this author in PubMed聽Google ScholarElisa TamarizView author publicationsYou can also search for this author in PubMed聽Google ScholarNorma Medina-VillalobosView author publicationsYou can also search for this author in PubMed聽Google ScholarJordi AndillaView author publicationsYou can also search for this author in PubMed聽Google ScholarMar铆a MarsalView author publicationsYou can also search for this author in PubMed聽Google ScholarPablo Loza-AlvarezView author publicationsYou can also search for this author in PubMed聽Google ScholarContributionsR.A., E.T., N.M.-V. and P.L.-A. conceived and designed the experiments. R.A., N.M.-V., and M.M., performed cell culture and experiments, R.A. made the data analysis, R.A., E.T., N.M.-V. and P.L.-A., interpreted the results. Instrumental development was done by J.A. and P.L.-A. The manuscript was written by R.A. with the contribution of all authors.Corresponding authorCorrespondence to Remy Avila.Ethics declarations Competing Interests The authors declare no competing interests. Additional informationPublisher鈥檚 note: Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.Electronic supplementary material Figure S1Rights and permissions Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article鈥檚 Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article鈥檚 Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/. Reprints and PermissionsAbout this articleCite this articleAvila, R., Tamariz, E., Medina-Villalobos, N. et al. Effects of near infrared focused laser on the fluorescence of labelled cell membrane. Sci Rep 8, 17674 (2018). https://doi.org/10.1038/s41598-018-36010-1Download citationReceived: 10 July 2018Accepted: 09 November 2018Published: 05 December 2018DOI: https://doi.org/10.1038/s41598-018-36010-1KeywordsFluorescence Recovery After Photobleaching (FRAP)Fluorescence RiseIncreased Mean FluorescenceImaging Plasma MembraneFRAP Experiments CommentsBy submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate. Sign up for the Nature Briefing newsletter 鈥?what matters in science, free to your inbox daily.

本文链接: http://cytoskeleton.immuno-online.com/view-69829.html

发布于 : 2025-03-14 阅读()