商品详细细胞骨架/SiR微管蛋白试剂盒/50 nmol SiR微管蛋白和1 umol维拉帕米/CY-SC002
细胞骨架/SiR微管蛋白试剂盒/50 nmol SiR微管蛋白和1 umol维拉帕米/CY-SC002
细胞骨架/SiR微管蛋白试剂盒/50 nmol SiR微管蛋白和1 umol维拉帕米/CY-SC002
商品编号: CY-SC002
品牌: Cytoskeleton
市场价: ¥10300.00
美元价: 6180.00
产地: 美国(厂家直采)
公司:
产品分类: 多肽合成
公司分类: peptide
联系Q Q: 3392242852
电话号码: 4000-520-616
电子邮箱: info@ebiomall.com
商品介绍
Details

SiR-tubulin is based on the microtubule binding drug Docetaxel. SiR-tubulin is fluorogenic, cell permeable and highly specific for microtubules. Sir-tubulin stains endogenous microtubules without the need for genetic manipulation or overexpression. Its emission in the far red minimizes phototoxicity and sample autofluorescence. SiR-tubulin is compatible with GFP and/or m-cherry fluorescent proteins. It can be imaged with standard Cy5 filtersets. SiR-tubulin can be used for widefield, confocal, SIM or STED imaging in living cells and tissue. Probe quantity allows 50 – 200 staining experiments.*

 

 

Optical properties

λabs   652 nm

λEm   674 nmεmax 1.0·105 mol-1·cm-1

*Based on the following conditions: 0.5 – 1 ml staining solution / staining experiments with 0.5 – 1 uM probe concentration. The number of staining experiments can be further increased by reducing volume or probe concentration.

 

Cytoskeleton, Inc. is the exclusive provider of Spirochrome, Ltd. products in North America.

About

For product Datasheets and MSDSs please click on the PDF links below.

Spirochrome Technical Tips and Ex/Em spectra in graphical form (PDF)

Citations

Lv, Q., Dong, F., Zhou, Y., Cai, Z. & Wang, G. RNA-binding protein SORBS2 suppresses clear cell renal cell carcinoma metastasis by enhancing MTUS1 mRNA stability. Cell Death Dis. 11, 1–12 (2020).

Ueki, H., Wang, I. H., Zhao, D., Gunzer, M. & Kawaoka, Y. Multicolor two-photon imaging of in vivo cellular pathophysiology upon influenza virus infection using the two-photon IMPRESS. Nat. Protoc. 15, 1041–1065 (2020).

Reclusa, P. et al. Improving extracellular vesicles visualization: From static to motion. Sci. Rep. 10, 1–9 (2020).

Tabdanov, E. D., Zhovmer, A. S., Puram, V. & Provenzano, P. P. Engineering Elastic Nano- and Micro-Patterns and Textures for Directed Cell Motility. STAR Protoc. 1, 100013 (2020).

“Fluorogenic probes for live-cell imaging of the cytoskeleton”; G. Lukinavičius, L.Reymond, E. D’Este, A. Masharina, F. Göttfert, H. Ta, A. Güther, M. Fournier, S. Rizzo, H. Waldmann, C. Blaukopf, C. Sommer, D. W. Gerlich, H.-D. Arndt, S. W. Hell & K. Johnsson; Nature Methods 11, 731–733, 2014.

 

“STED Nanoscopy Reveals the Ubiquity of Subcortical Cytoskeleton Periodicity in Living Neurons”; E. D’Este, D. Kamin, F. Göttfert, A. El-Hady, S. W. Hell; Cell Reports , Volume 10 , Issue 8 , 1246 – 1251, 2015.

 

“A near-infrared fluorophore for live-cell super-resolution microscopy of cellular proteins”; G. Lukinavičius, K. Umezawa, N. Olivier, A. Honigmann, G. Yang, T. Plass, V. Mueller, L. Reymond, I. R. Corrêa Jr, Z. Luo, C. Schultz, E. A. Lemke, P. Heppenstall, C. Eggeling, S. Manley & K. Johnsson; Nature Chemistry 5, 132–139, 2013.

 

“Dynamic actin filaments control the mechanical behavior of the human red blood cell membrane”; D. S. Gokhin, R. B. Nowak, J. A. Khoory, A. de la Piedra, I. C. Ghiran and V. M. Fowler; Mol. Biol. Cell; February 25, 2015.

 

“A cleavable cytolysin-neuropeptide Y bioconjugate enables specific drug delivery and demonstrates intracellular mode of action”; V. M. Ahrens, K. B. Kostelnik, R. Rennert, D. Böhme, S. Kalkhof, D. Kosel, L. Weber, M. von Bergen and A. G. Beck-Sickinger; J. Control. Release; 209:170-178, 2015.

 

“Red Si–rhodamine drug conjugates enable imaging in GFP cells”; E. Kim, K. S. Yang, R. J. Giedt and R. Weissleder; Chem. Commun., 50, 4504-4507, 2014.

 

“A marginal band of microtubules transports and organizes mitochondria in retinal bipolar synaptic terminals”; M. Graffe, D. Zenisek, and J. Taraska; J. Gen Physiol. Vol. 146 No.1: 109-117, 2015.

 

 

Application Notes

 

“A Bright Dye for Live-Cell STED Microscopy”; S. Pitsch, I. Köster.

Faqs

Q1. What is STED microscopy and how does it work?

A1. STED microscopy stands for Stimulated Emission Depletion microscopy.  It is one type of super resolution microscopy which allows the capture of images with a higher resolution than conventional light microscopy which is constrained by diffraction of light.  STED uses 2 laser pulses, one is the excitation pulse which excites the fluorophore, causing it to fluoresce.  The second pulse, referred to as the STED pulse, de-excites the fluorophore via stimulated emission in an area surrounding a central focal spot that is not de-excited and thus continues to fluoresce.  This is accomplished by focusing the STED pulse into a ring shape, a so-called donut, where the center focal spot is devoid of the STED laser pulse, conferring high resolution to the fluorescent area (Fig. 1; see Ref. 1 for more details on STED microscopy).

fig1-faq

Figure 1. STED microscopic image of microtubules labeled with SiR-tubulin in human primary dermal fibroblasts.

Q2. Why is the SiR actin (or tubulin) probe good for STED microscopy?

A2. STED microscopy offers the ability to study cellular details on a nanometermolar scale in vivo.  To take advantage of this super resolution microscopy, one must be able to select with high specificity the area to be examined using fluorescent probes.  In addition, the fluorescent probes must be bright, photostable, exhibit no or little phototoxicity, be excited and emit in the far red spectrum.  In addition, if the probe is to be used for live cell imaging (thus avoiding fixation artifacts that occur when cells are fixed), high cell permeability is necessary.  The SiR actin and tubulin probes fulfill all of these requirements.  In short, the combination of STED and SiR probes allows for unparalleled fluorescent visualization of subcellular actin and tubulin/microtubule structures and their physical characterization in living cells, (see Fig. 2 and Ref. 2). 

Neuron_actin_1
Neuron_actin_closup2_1

Figure 2. STED images of cultured rat hippocampal neurons stained with SiR-actin. Bottom image is a close-up view of part of the top image to clearly visualize actin rings (stripes) with 180 nm periodicity. Courtesy Of Elisa D"Este, MPI Biophysical Chemistry, Göttingen.

Q3. What are the filter sets for these probes?

A3. The SiR actin and tubulin probes are visualized with standard Cy5 filters.  Optimal excitation is 650 nm and emission is 670 nm.  We recommend filters with an excitation of 630 + 20 nm and an emission of 680 + 20 nm (Fig. 3).  

faq-fig3

Figure 3. Excitation (blue) and emission (red) spectra for SiR probes.

Q4. Why do the SiR probes have a low background compared to other fluorophores?

A4. SiR probes are excited by and emit light in the near infrared/far red spectral range, thus avoiding the use of shorter wavelengths such as blue and green light that typically autofluoresce, causing higher background signals.  SiR-coupled probes possess two physical states: 1. a non-fluorescent, closed off-state (spirolactone)  and 2. an open, highly fluorescent on-state (zwitterion).  The binding of the probe to its ligand target favors the highly fluorescent open state while the free unbound probe exists in the closed, non-fluorescent state (Fig. 4).  The fluorescence amplification is 100-fold from the unbound to bound state. This results in a highly sensitive biosensor in which the majority of fluorescence occurs only in the bound state (see Refs. 3 and 4). 

faq-fig4

Figure 4. SiR derivatives exist in equilibrium between the fluorescent zwitterionic (open) form (left structure) and the non-fluorescent spiro (closed) form (right structure).

Q5: Are the SiR probes stable at room temperature?

A5: Yes, the probes are stable at room temperature for a few days.  However, it strongly depends on the probe and the solvent.  Thus, it is recommended to store all of the probes or solutions at –20°C.

 

Q6: Are SiR-actin and SiR-tubulin toxic to cells?

A6: Yes, above a certain threshold both probes show some effect on cell proliferation and altered actin or microtubule dynamics.  However, the probes are orders of magnitude less toxic than their parent drug.  In HeLa cells, neither actin nor microtubule dynamics were altered at concentrations below 100 nM.  At this concentration, SiR probes efficiently label microtubules and F-actin, allowing for the capture of high signal to noise images.

 

Q7: Do the probes work on fixed cells?

A7: SiR-actin probes can be used with PFA-fixed cells.  SiR-actin labels F-actin in PFA-fixed cells as efficiently as phalloidin derivatives.  SiR-tubulin labels microtubules only in ethyleneglycol-bis-succinimidyl-succinate (EGS)-fixed cells.  However, a selective labeling of centrosomal microtubules of PFA-fixed cells was observed.  SiR-actin and SiR-tubulin are not suitable for methanol-fixed cells.

 

Q8: Is it possible to image SiR-probes by STORM?

A8: No—under the very high light intensities typically used in STORM imaging, a phototoxic effect is observed on live cells.

 

Q9: Which organisms and tissues are stained by SiR-probes?

A9: This list describes only cell lines, tissues, or organisms that have been reported to work.  Omission of a cell line, tissue, or organism does not mean that the SiR-probes will not work with the specific cells, tissues, or organisms.

 

Homo sapiens: U2OS, fibroblasts, HeLa, HUVEC, MCF-10A, HCT-116, A549, erythrocytes

Mus musculus: C2C12, IA32, skeletal muscle, primary cardiomyocyte, primary oocyte

Rattus norvegicus: primary hippocampal neurons, primary cortical neurons, NRK

Cercopithecus aethiops: COS-7

Mesocricetus auratus: BHK

Drosophila melanogaster: Notum epithelium, S2

Didelphis marsupialis: OK cells

 

Q10. Do SiR-probes work in 3D cell cultures?

A10: Yes, the probes are able to stain cells in a 3D growth environment.

 

Q11: What are the correction factors CF260 and CF280for the SiR fluorophore?

A11: CF260 = 0.116 and CF280 = 0.147

 

References

1. Hell S.W. and Wichmann J. 1994. Breaking the diffraction resolution limit by stimulated emission: stimulated-emission-depletion fluorescence microscopy. Opt. Lett. 19, 780-782.

2. D’Este E. et al. 2015. STED nanoscopy reveals the ubiquity of subcortical cytoskeleton periodicity in living neurons. Cell Rep. 10, 1246-1251.

3. Lukinavicius G. et al. 2013. A near-infrared fluorophore for live-cell super-resolution microscopy of cellular proteins. Nat. Chem. 5, 132-139.

4. Lukinavicius G. et al. 2014. Fluorogenic probes for live-cell imaging of the cytoskeleton.Nature Methods. 11, 731-733.

品牌介绍
Cytoskeleton,Inc.成立于1993年。自成立以来,我们一直在不断扩大产品范围。Cytoskeleton,Inc.很高兴为药物筛选,信号转导和细胞骨架研究提供广泛的试剂盒和产品。我们专注于纯化蛋白的生产和易于使用的试剂盒,以研究生化和细胞过程。我们的试剂盒既可用于基础研究或小型筛查的少量样品,也可用于大型筛查的高通量规模除了我们现有的产品外,我们还提供产品系列中微管,微管蛋白,运动蛋白,小G蛋白效应物,GAP,GEF和其他几种蛋白的药物筛选服务。有关更多信息,请参见我们的药物筛选服务页面。如果您想从市场上购买到特定产品,请随时与我们联系。我们在这里为您提供帮助。由于我们的科学家在各自的专业领域都有多年的工作经验,因此我们能够提供高质量的产品。自1993年成立以来,我们以合理的价格生产优质的产品而闻名。