商品详细Cytoskeleton/Rac1 G-LISA Activation Assay (Luminescence format) - 96 assays/96 assays/BK126
Cytoskeleton/Rac1 G-LISA Activation Assay (Luminescence format) - 96 assays/96 assays/BK126
Cytoskeleton/Rac1 G-LISA Activation Assay (Luminescence format) - 96 assays/96 assays/BK126
商品编号: BK126
品牌: Cytoskeleton
市场价: ¥17400.00
美元价: 10440.00
产地: 美国(厂家直采)
公司:
产品分类: 多肽合成
公司分类: peptide
联系Q Q: 3392242852
电话号码: 4000-520-616
电子邮箱: info@ebiomall.com
商品介绍
Details

Product Uses Include

  • Rac1 signaling pathway studies
  • Rac1 activation assays with primary cells
  • Studies of Rac1 activators and inactivators
  • Rac1 activation assays with limited material
  • High throughput screens for Rac1 activation/inhibition

IntroductionThe G-LISA series of Small G-Protein Activation Assays are ELISA based assays with which you can measure the GTP form of small G-proteins from lysates of cells or tissues and all in less than 3 h. The level of activation is measured with luminescence. For a more detailed introduction on G-LISA™ assays and a listing of other available G-LISA™ kits, see our main G-LISA™ page. The Rac1 G-LISA™ Activation Assay (Cat.# BK126) measures the level of GTP-loaded Rac1 protein in cell lysates, this is in contrast to Cat. BK125 which does not distinguish between activated Rac1,2 or 3. For a kit to measure RhoA activation please check webpage BK124.

The Rac1 G-LISA Activation Assay is very sensitive and has excellent accuracy for duplicate samples. See G-LISA™ FAQs tab on our G-LISA™ page for more details.

Kit contentsThe kit contains sufficient reagents to perform 96 Rac activation assays. Since the Rac-GTP affinity wells are supplied as strips and the strips can be broken into smaller pieces, each kit can be used for anywhere from one to multiple assays. The following components are included in the kit:

  1. 96 Rac-GTP affinity wells (divisible into 96 individual wells)
  2. Lysis buffer
  3. Binding buffer
  4. Antigen presenting buffer
  5. Wash buffer
  6. Antibody dilution buffer
  7. Anti-Rac1 antibody
  8. HRP-labeled secondary antibody
  9. Positive control Rac1 protein
  10. Protease inhibitor cocktail (Cat. # PIC02)
  11. Luminescence detection reagents
  12. Precision Red™ Advanced protein assay reagent (Cat. # ADV02)
  13. Manual with detailed protocols and extensive troubleshooting guide

Equipment needed

  1. 96-well plate luminometer
  2. Multichannel or multidispensing pipettor
  3. Orbital microplate shaker capable of at least 200 rpm shaking (400 rpm is optimal)

Example resultsSerum starved Swiss 3T3 cells were stimulated with the Rac activating compound EGF and Rac activation was measured with the G-LISA method (Fig 1 and 2).

BK126_S-N

Figure 1. Rac1 activation by EGF measured by G-LISA™ kit BK126. Swiss 3T3 (mouse) cells were serum starved for 24 h and treated with EGF (10ng/ml for 2.5 min) or buffer only (SS). 10 µg of cell lysates were subjected to the G-LISA™ assay. Luminescence measured over 100 milli-second.

BK126_cv

Figure 2. Rac  activation by EGF measured by G-LISA™.  Swiss 3T3 cells were serum starved (SS) for 24 h and treated with EGF (10 ng/ml for 2 min). 60, 30, 15, 7.5, 2.5 µg of cell lysates were subjected to the G-LISA™ assay. Luminescence was measured over 10 milli-seconds. 500 µg of the same lysates were subjected to the traditional PAK pull-down assay (shown in inset, Cat.# BK035).

Go to main G-LISA™ page

G-LISA Products:Cdc42 G-LISA™ Activation Assay, colorimetric format (Cat.# BK127)Rac1,2,3 G-LISA™ Activation Assay, colorimetric format (Cat.# BK125)RhoA G-LISA™ Activation Assay, colorimetric format (Cat.# BK124)RhoA G-LISA™ Activation Assay, luminescence format (Cat.# BK121)

Associated Products:Anti-Cdc42 monoclonal antibody (Cat.# ACD03)Anti-Rac1 monoclonal antibody (Cat.# ARC03)Anti-RhoA monoclonal antibody (Cat.# ARH03)

About

For product Datasheets and MSDSs please click on the PDF links below.   For additional information, click on the FAQs tab above or contact our Technical Support department at tservice@cytoskeleton.com

  •  G-LISA Activation Assay Technical Guide download here
  • For our G-LISA Data Analysis (Luminescence) Excel Template please download here.

 

    Citations

    Binker et al., 2011. TGF-β1 increases invasiveness of SW1990 cells through Rac1/ROS/NF-κB/IL-6/MMP-2. Biochem. Biophys. Res. Comm. v 405, pp 140-145.

    Sayedyahossein et al., 2012. Essential role of integrin-linked kinase in regulation of phagocytosis in keratinocytes. FASEB J. doi: 10.1096/fj.12-207852.

    Kikuchi et al., 2012. Protein kinase C iota as a therapeutic target in alveolar rhabdomyosarcoma. Oncogene. doi:10.1038/onc.2012.46.

    Eggers et al., 2012. STE20-related Kinase Adaptor Protein α (STRADα) Regulates Cell Polarity and Invasion through PAK1 Signaling in LKB1-null Cells. J. Biol. Chem. v 287, pp 18758-18768.

    Vives et al. (2011). The Rac1 exchange factor Dock5 is essential for bone resorption by osteoclasts. Journal of Bone and Mineral Research 26 ,1099.

    McHenry et al. (2010). P190B RhoGAP has pro-tumorigenic functions during MMTV-Neu mammary tumorigenesis and metastasis. Breast Cancer Res.

    Johanna et al. (2010). Rac1 activity changes are associated with neuronal pathology and spatial memory long-term recovery after global cerebral ischemia. Neurochem International 57 ,762-773.

    Baumer et al., 2009. J Cell Physiol. 220, 716

    Heckman-Stoddard et al. (2009). Haploinsufficiency for p190B RhoGAP inhibits MMTV-Neu tumor progression. Breast Cancer Research 11 ,http://breast-cancer-research.com/content/11/4/R61.

    Chastre et al. (2009). TRIP6, a novel molecular partner of the MAGI-1 scaffolding molecule, promotes invasiveness. FASEB Journal 23 ,916–928.

    Ramirez et al., 2008. J Immunol. 180, 1854

    Moniz et al. (2008). WNK2 modulates MEK1 activity through the Rho GTPase pathway. Cellular Signalling 20 ,1762-68.

    Pontow et al., 2007. Virology. 368, 1

    Faqs

    Question 1: There is less than a 2-fold difference in signal intensity between my positive control and lysis buffer blank. Why?

    Answer 1: To accurately measure luminescence signal intensity between the positive control and buffer blank, please check the instrument settings on the luminometer (see below for suggestions). We also recommend running some “set-up” experiments with just the buffer blank and positive control to determine optimal settings for detecting the positive control signal 3-5 fold higher than the buffer blank. It is also important to remember to use a fresh control protein tube for each run of positive control samples. Do not store and re-use the positive control.

    Machine Settings

    Gain

    Gain controls the sensitivity of the machine. Most luminometers do not allow manual alteration of gain and use an auto-calibration or limited calibration function. Turn off auto-settings and auto-calibration to use the machine in manual mode. It is important to contact the luminometer manufacturer or consult the user’s manual to determine the best way to alter the machine sensitivity. If gain can be altered, one should read at low, medium and high gains to determine the reading within the linear range of the assay (positive control should be 3-5X higher than blank). Gain range varies with instrument. For example, gain in the Tecan GmbH SpectroFluor Plus ranges from 0 - 150 (where 150 is the highest).

    Integration Time

    This parameter can be varied on most machines. It is a good idea to set the machine at the lowest integration time (usually 10 – 100 ms). Integration times greater than 200 ms are likely to read out of the linear range of the assay and may require lowering of gain or dilution of primary and/or secondary antibodies.

    Shaking

    Most machines give the shaking option. The recommended setting is 5 sec shake, medium orbital speed before read. This option is not essential to the assay.

    Temperature

    Room temperature

    Plate type

    Any setting that specifies 96 well flat, white will be sufficient.

    Filters

    Luminescence does not require excitation or emission filters so the filter spaces should be left blank. If this is not an option, excitation can be set at any value and emission should be set between 400-500nm, with 430-445 as optimal setting.

    Question 2: My arbitrary luminescence units (ALU) or relative luminescence units (RLU) are very different from what is depicted in the manual. Why?

    Answer 2: This is very typical as the luminescence units will vary from luminometer to luminometer based on the machine’s sensitivity and instrument settings. The important information to take note of is what the relationship is between buffer blank and positive control luminescence values. The positive control signal should be 3-5 fold greater than the buffer blank luminescence signal. If that is the case, then the G-LISA assay is functioning in the linear range and experimental samples can now be processed.

    If you have any questions concerning this product, please contact our Technical Service department at tservice@cytoskeleton.com.

    品牌介绍
    Cytoskeleton,Inc.成立于1993年。自成立以来,我们一直在不断扩大产品范围。Cytoskeleton,Inc.很高兴为药物筛选,信号转导和细胞骨架研究提供广泛的试剂盒和产品。我们专注于纯化蛋白的生产和易于使用的试剂盒,以研究生化和细胞过程。我们的试剂盒既可用于基础研究或小型筛查的少量样品,也可用于大型筛查的高通量规模除了我们现有的产品外,我们还提供产品系列中微管,微管蛋白,运动蛋白,小G蛋白效应物,GAP,GEF和其他几种蛋白的药物筛选服务。有关更多信息,请参见我们的药物筛选服务页面。如果您想从市场上购买到特定产品,请随时与我们联系。我们在这里为您提供帮助。由于我们的科学家在各自的专业领域都有多年的工作经验,因此我们能够提供高质量的产品。自1993年成立以来,我们以合理的价格生产优质的产品而闻名。